Get to know our latest news
Field notes, technical guides and project records from our engineering and export teams — written for the people who specify, install and maintain plastic pipeline systems.
Technical GuidesPE100 vs PE80: What the Grade Difference Actually Means on Site
Both grades can look identical in a stack of black pipe. The difference shows up in pressure rating, wall thickness and how the pipe survives a rocky trench — here is how to read it before you order.
Read More →
Technical GuidesReading PE Pipe Markings: SDR, Pressure Rating and Safety Factor
The print line along a PE pipe carries everything you need to confirm the order — grade, SDR, pressure class, standard and batch. Here is how to decode it in under a minute, and the three markings buyers most often misread.
Read More →
Technical GuidesButt Fusion vs Electrofusion: Choosing the Right Jointing Method for PE Pipe
The method is usually decided by whoever owns the machine, not by the pipe or the site. That is how projects end up with the wrong joint in the wrong place — a comparison of cost, tolerance, access and inspection.
Read More →
Technical GuidesPVC-U Pipe for Rural Water Supply: A Specification Checklist
Rural schemes fail on the details that never make it into the bill of quantities: pressure class at the lowest point, expansion gaps at noon, solvent cement in the sun. A practical checklist for buyers and engineers.
Read More →
Technical GuidesSolvent Cementing PVC Pipe: Five Mistakes Behind Most Joint Failures
A solvent-welded joint either works for forty years or leaks in the first week, and the difference is almost always one of five procedural mistakes. None of them are visible after the pipe is buried.
Read More →
Technical GuidesMPP Cable Conduit: Selection, Bending and Jointing for Underground Power
MPP conduit is chosen for two reasons — it takes heat and it can be pulled through a bore. Both come with conditions that decide whether the duct is still round when the cable arrives.
Read More →
Technical GuidesPVC Drainage Pipe Slope and Venting: Getting the Hydraulics Right
A drain that is too flat silts up; a drain that is too steep empties the trap and lets sewer gas into the building. Both are slope decisions, and both are usually made by eye on site.
Read More →
Technical GuidesSN4 or SN8? Reading Ring Stiffness for HDPE Double-Wall Corrugated Pipe
Ring stiffness is a pipe property, but deflection is a soil-structure property. Half the corrugated pipe failures we see are pipes that met their SN class and still flattened in the trench.
Read More →
Latest News
- PE100 vs PE80: What the Grade Difference Actually Means on SiteOct.28.2026
- Reading PE Pipe Markings: SDR, Pressure Rating and Safety FactorOct.22.2026
- Butt Fusion vs Electrofusion: Choosing the Right Jointing Method for PE PipeOct.16.2026
- PVC-U Pipe for Rural Water Supply: A Specification ChecklistOct.09.2026
- Solvent Cementing PVC Pipe: Five Mistakes Behind Most Joint FailuresOct.02.2026
- MPP Cable Conduit: Selection, Bending and Jointing for Underground PowerSep.25.2026
- WhatsApp: +86 158 6388 5978
- E-mail: Gsl164@163.com
- Tel: +86 158 6388 5978
- Address: Linyi, Shandong, China